Troubleshooting

2 min read · updated 23 Jul 2026

ProblemChecks and corrective action
The level meter does not moveConfirm Capture from and Device in Settings. Check Windows input/output levels, mute state and audio routing. Choose Refresh after connecting or enabling a device.
The wrong audio is being recordedSelect the station program feed rather than the computer microphone. For playback capture, verify that the chosen Windows playback endpoint is the one carrying the broadcast.
Recordings are silent or distortedCheck the meter. Very low levels may be inaudible; peaks at or near 0 dBFS may clip. Adjust the source or interface level rather than relying on playback volume.
Automatic recording does not startEnable Auto, confirm green Scheduler cells cover the current time, check the computer clock and review the event log for device or folder errors.
Files are not appearing in ArchiveVerify the output folder, write permission and available disk space. Check whether automatic deletion is removing files sooner than expected.
Segments start at unexpected timesEnable Align splits to the clock when you want files to begin on fixed clock boundaries.
Archive playback is inaudibleSelect the correct Playback device in Settings and check the Windows volume mixer.
Silence emails do not arriveEnable notifications, confirm the destination and SMTP fields, match TLS and port requirements, use Test and check spam filtering or provider security settings.
Too many silence alerts are sentIncrease the silence duration, choose a more-negative threshold, or confirm that quiet programming is not falling below the current threshold.
The application is accidentally closedEnable Ask on close. For unattended systems, also consider startup with Windows and automatic restart.
External trigger does not start or stop recordingConfirm the selected trigger type, COM/MIDI device, baud rate, channel, Note/CC or sense line. Verify that no other program has opened the COM port. Match serial commands exactly, try MIDI channel any during testing, and use Invert if a contact closure reports the opposite state. Review the event log after each test.

Information to collect before requesting support

  • BroadcastLogger version and Windows version.
  • The selected Capture from mode, device name, codec, sample rate, bit rate and channels.
  • A screenshot of the main window and relevant Settings panel.
  • The exact time the problem occurred and the corresponding event-log message.
  • Whether a manual recording succeeds and whether the file plays in another audio player.

DO NOT SHARE PASSWORDS: Remove SMTP passwords, account credentials and private file paths from screenshots or support messages.

Was this page helpful?

Still stuck? Ask in the community forum .