Reading the display

2 min read · updated 23 Jul 2026

The status panel is styled to match BroadcastLogger, so the two read the same way when they're side by side in a rack room.

ElementShows
Large readoutElapsed time while syncing; otherwise a live countdown to the next run. Dashes when AUTO is off. Turns red on error.
AUTO / MANUAL / OFF / ERRCurrent mode.
Filled pillThe active sync mode, e.g. NEW + CHANGED + PRUNE.
Right-hand readoutConnection state — OFFLINE, CONNECTING, CONNECTED, TRANSFERRING or ERROR — with the host.
FILE meterProgress through the current file.
RATE meterTransfer throughput, log-scaled, with amber and red at the top of the range.
TODAY timeline24 hours in half-hour cells. Past syncs lit; the next scheduled run boxed and highlighted.
Job nameAbove the digits: the running job, or the one due next.
Amber footerThe current file while transferring, otherwise the last result — time, counts of new / same / deleted, total size — plus the next run time.

The colon blinks while a sync is running, which is the quickest way to tell an active transfer from a stalled one at a glance.

A RATE METER PINNED AT THE TOP isn't necessarily good news on a shared connection — if the mirror is saturating the link during office hours, consider moving the schedule to overnight.

Was this page helpful?

Still stuck? Ask in the community forum .